Refrigeration unit not maintaining temperature — reading -8°C against setpoint -18°C after 40min run. Compressor cycling irregularly.

Out of serviceSource · pre startType · driver assessedrefrigeration
Sub-jobs
1/2
complete
Affected assets
Opened by
Ravi Sharma
23 Aug 2026 · 2 days ago
Safety classification
Out of service
Return-to-service
Pending

Sub-job workflow

Every party, every action, every timestamp — the audit trail.

AFN-00127faultcompleted
MW
Marcus Webb

Initial assessment. Suspect refrigerant leak or compressor issue. Refrig-tech callout required.

Work completed
Confirmed low refrigerant pressure. Isolated leak to evaporator coil connection. External refrig tech required for repair.
Assigned 23 Aug 2026Started 23 Aug 2026Completed 24 Aug 2026
ARP-00370repairassigned
DM
Dave Morrison· Northside Diesel Services

Replace evaporator coil O-ring, recharge refrigerant system, pressure-test.

Assigned 24 Aug 2026